Nevada Lic. No. 61031

Free EstimateCall Us Today: 775-356-0444

Advanced OverheadGarage Door Company

Garage Door Won't Close

The short answer

A garage door that stops and reverses before it closes is most often reacting to its photo eyes, the safety sensors near the floor, which are blocked, dirty or out of line. Advanced Overhead Garage Door Company repairs and replaces garage door openers, sensors and wall controls in the Reno area and across Northern Nevada; call 775-356-0444.

Safety first

Never hold the wall button down to force a door closed over a fault, and never turn up the opener's force setting. Both defeat the safety reverse that protects people and pets.

Call 775-356-0444

Three white raised-panel garage doors on a stucco home

Photo eyes: the usual cause

Photo eyes are two small sensors mounted on each side of the door, a few inches off the floor. One sends an invisible beam and the other receives it. If anything breaks the beam, or the receiver cannot see it, the opener will not close the door. The U.S. Consumer Product Safety Commission publication on garage door safety places them 4 to 6 inches above the floor.

Federal safety rules for these openers require the operator to monitor for the presence and correct operation of the sensor at least once during each close cycle, which is why a fault shows up as a refusal to close, not as a door that closes anyway.

Safe checks before you call

All of these are done with the door open or closed and your hands nowhere near the door's moving parts.

  1. Look for anything in the beam: a stored box, a leaning broom, a bag, a cobweb or a pet's bed.
  2. Wipe both sensor lenses with a clean, soft cloth. Dust and moisture can block the beam.
  3. Check the two indicator lights. Most sensors show a steady light when aligned. A dark or blinking light on one side points to a bump or a bent bracket.
  4. Gently nudge a sensor back until its light turns steady. Do not bend the bracket hard or loosen the screws that hold the opener.
  5. Watch for sunlight hitting a lens directly at certain times of day. Shading the sensor with a piece of cardboard for a test will show whether glare is the cause.

If the lights are steady and the door still reverses, run the test in our safety reversal test guide to see whether the opener reverses on contact. The guide uses a 2x4 on the floor in the door's path, the method the CPSC recommends, and you should repeat it monthly.

White sectional garage door on a gray house with the service truck in front

What else can stop a door from closing?

When the sensors are fine, the cause is usually one of the items in the table. Several of them need a technician, because the opener's travel limits and the door's track are involved.

What else can stop a door from closing?
What you seeLikely causeWhat to do
Sensor light dark or blinkingWire cut or pinched near the sensorLook for a damaged wire; call if you find one
Door reverses just before the floorDown-travel limit set too shortCall; the limit setting is part of an opener adjustment
Door stops part-way, opener humsSomething in the track, or a bent trackDo not force it; call
Opener does not respond to the wall controlControl fault or a wire problemCheck the lock button; see our remotes and keypads page
Door crooked, one side lowerCable or roller problemStop using the door; see broken garage door repair

Safe checks versus a service call

Cleaning, clearing the beam and gently re-aiming a sensor are fine for a homeowner. Adjusting limit settings, changing force settings, replacing sensor wire or anything touching the door's springs, cables and tracks is work for a technician. DASMA, the Door and Access Systems Manufacturers Association, recommends monthly safety checks and an annual visit from a trained door systems technician.

We repair openers of various brands, and we are an authorized LiftMaster dealer. Our opener repair service covers sensors, controls and circuit boards, and we give a free estimate. We guarantee all our work.

Garage Door Won't Close: Questions

Why does my garage door go down and then back up?

The opener is reversing, which usually means the photo eyes see something in the beam or are out of line. It can also mean the door meets resistance before the floor. Clean and check the sensors first, then call us if it continues.

Why does the door close only when I hold the button?

Many openers allow a manual close while the button is held when the sensors are not working. It is a sign of a sensor fault, not a fix. Have the sensors and wire checked rather than closing the door this way each day.

Can sunlight stop a garage door from closing?

Yes. Strong sun shining straight into a sensor lens can confuse it, usually for a short time in the morning or evening. Shading the lens often settles it; if not, a technician can re-aim or relocate the sensor.

Should I raise the force setting to make it close?

No. A higher force setting can stop the door from reversing when it should, which defeats a safety feature. If the door needs more force to close, something is wrong, and we recommend a call.

More questions and answers

Contact Us for Quick Job Quotes and More Information.

Call 775-356-0444 or 775-883-0444, or send the form for a free estimate. Emergency and same-day service available 24/7.